F-900 Portable Ethylene Analyzer

Highly-sensitive, portable ethylene measurement for controlled atmosphere environments.

Improving ethylene analysis workflows in research and industry.

Providing quality assurance professionals and researchers with the data they need to manage facilities with data-driven insights.

F-900 Portable Ethylene Analyzer

Rugged and portable

Individually machined in the USA, the Portable Ethylene Analyzer is designed to function as a portable instrument or permanent fixture.

Intuitive user interface

The Portable Ethylene Analyzer’s simple and intuitive user interface makes data collection a breeze.

Anti-glare LCD screen

Designed with the user in mind, the Portable Ethylene Analyzer’s transflective LCD screen is easily viewed in any lighting conditions.

Built in terminal block

Use your Portable Ethylene Analyzer to easily control ventilation systems with the built in terminal block.

F-900 Portable Ethylene Analyzer
1

Rugged and portable

Individually machined in the USA, the Portable Ethylene Analyzer is designed to function as a portable instrument or permanent fixture.

2

Intuitive user interface

The Portable Ethylene Analyzer’s simple and intuitive user interface makes data collection a breeze.

3

Anti-glare LCD screen

Designed with the user in mind, the Portable Ethylene Analyzer’s transflective LCD screen is easily viewed in any lighting conditions.

4

Built in terminal block

Use your Portable Ethylene Analyzer to easily control ventilation systems with the built in terminal block.

More than 230+ published
research papers

using LAI & canopy analysis

Request a live demonstration

High precision gas analysis in the lab or packing house

Non-destructive measurement

Take in-situ ethylene flux measurements from fruits and leaves non-destructively using the F-900 Research Kit.

CO2 and O2 sensing

Fully customize the Portable Ethylene Analyzer to fit your needs with optional, high-performance CO2 and O2 sensors.

Highly sensitive ethylene sensors

Experience unrivaled portable ethylene (C2H4) sensitivity with detection down to 0.025 ppm (25ppb).

Internal data logging and storage

Store thousands of measurements and transfer data easily using the included 4GB SD card.

User-adjustable sampling rate

Take full control of your ripening gas measurement with on-demand monitoring of gas fluctuations with user-selected regularity and real-time accuracy.

Wide temperature and humidity range

Gather reliable data in environments ranging from 0°C – 45°C and 0 – 90% non-condensing humidity.

  • Does this product come with a warranty?

  • All devices from Felix Instruments – Applied Food Science come with a 12- month warranty at the point of sale. The warranty covers repairing and replacing defective parts of the instrument that were manufactured directly by Felix Instruments. The warranty does not cover wear and tear, neglect, misuse, accident, or excessive deterioration. Further, unauthorized repair and alteration by an unauthorized party voids the warranty. More information can be found in the operation manual of your instrument.

  • How does the sample reach the analyzer?

  • In Continuous monitoring mode, gas enters through the inlet of the device and is drawn in by the pump. The inlet can be free of tubing, in which case it will measure ambient air, or it can be connected by tubing to a chamber or other measurement location or apparatus. In GC Emulation Mode samples are injected into a special port that connects to both the inlet and outlet of the device

  • What is the difference between the F-900RK and the F-900?

  • The F-900 is the ethylene analyzer. The F-900RK is an optional accessory kit for the F-900 that includes a 2L chamber, connetion wand, injection port kit for small gas samples, and a hard carrying case.

  • Is the Portable Ethylene Analyzer waterproof?

  • The Portable Ethylene Analyzer is not designed to be waterproof and should not be used underwater. The Portable Ethylene Analyzer is designed to be water-resistant. Use in light rain is fine, however, there are electronics inside of the Portable Ethylene Analyzer that can be damaged from water entering the instrument, so it is not recommended to use the Portable Ethylene Analyzer during heavy rainfall.

Have additional questions?

Click the link below to speak with one of our staff scientists about your specific application.

Click here to schedule a consultation

Specifications

Air Sampling Rate: 80 ml/min
Measuring Rate: 1 second intervals, open or closed loop
Display: Sunlight visible transflective LCD
Operating Environment: 0°C – 45°C; 0-90% humidity non-condensing
Battery Capacity: 5 hours – Rechargeable Li-Ion (5000 mAh)
Dimensions: 255 mm (L) x 210 mm (W) x 138 mm (H; includes body with legs)
Weight: 2.96 kg
Enclosure: Anodized aluminum
Warm-up Time: 1 min (C2H4)

C2H4 PPB Sensor

Sensor Type: Electrochemical
Range: 0-10 ppm
Resolution: 0.001 ppm
Accuracy: 5% ± 0.025 ppm
Lower Detection Limit: 0.025 ppm (25 ppb)

C2H4 PPM Sensor

Sensor Type: Electrochemical
Range: 0-200 ppm
Resolution: 0.1 ppm
Accuracy: 5% ± 0.5 ppm
Lower Detection Limit: 0.5 ppm

CO2 PPM Sensor (optional)

Sensor Type: Low-power non-dispersive infrared gas analyzer
Range: 0-2000 ppm
Resolution: 0.1 ppm
Accuracy: 5%

CO2 PCT Sensor (optional)

Sensor Type: Infrared sensor, pyroelectric detector
Range: 0-20%
Resolution: 0.01%
Accuracy: 5%

O2 Sensor (optional)

Sensor Type: Electrochemical
Range: 0-100%
Resolution: 0.1%
Accuracy: 5%

Highly-sensitive, portable ethylene measurement for controlled atmosphere environments.

Accurate and efficient ethylene management for research and QA.