F-960 Ripen It! Gas Analyzer

Rapid, precise measurement of ethylene, CO2 and O2

Manage high-ethylene commodities with ease.

The Ripen It! Gas Analyzer offers unparalleled precision in measuring high-quantity ripening gasses.

F-960 Ripen It! Gas Analyzer

Backlit LCD screen

Never struggle to see your readings, even in dimly-lit storage environments.

Lightweight & heavy duty

Individually machined in the USA, the Store It! Gas Analyzer’s highly durable, aluminum construction gives you peace of mind without sacrificing weight.

Automated data capture

Never lose a data point with up-to-the-second autosave.

Internal data logging

Store and review thousands of records on the Three Gas Analyzer’s removable 16gb SD card.

F-960 Ripen It! Gas Analyzer
1

Backlit LCD screen

Never struggle to see your readings, even in dimly-lit storage environments.

2

Lightweight & heavy duty

Individually machined in the USA, the Store It! Gas Analyzer’s highly durable, aluminum construction gives you peace of mind without sacrificing weight.

3

Automated data capture

Never lose a data point with up-to-the-second autosave.

4

Internal data logging

Store and review thousands of records on the Three Gas Analyzer’s removable 16gb SD card.

Request a live demonstration

Easily gather data for better ripening decisions

All-day battery life

With an 8.5 hour battery life and rechargeable 3400 mAh replacement batteries included, you can work confidently without interruption.

Painless data transfer

With bluetooth and WIFI capabilities, rapid data transfer has never been easier.

Remove non-ethylene hydrocarbons

Achieve pinpoint accuracy in your ethylene readings with the PolarCept! water filter.

User-selected sampling modes

Choose from headspace or continuous sampling depending on your unique needs.

Wide temperature and humidity range

Gather reliable data in environments ranging from 0°C – 50°C and 0 – 90% non-condensing humidity.

5 data points recorded

Each sampling event records CO2 concentration, O2 concentration, date & time, RH, and GPS location.

  • Is the Ripen It! Gas Analyzer waterproof?

  • The Ripen It! Gas Analyzer is not designed to be waterproof and should not be used underwater. The Ripen It! Gas Analyzer is designed to be water-resistant. Use in light rain is fine, however, there are electronics inside of the Ripen It! Gas Analyzer that can be damaged from water entering the instrument, so it is not recommended to use the Ripen It! Gas Analyzer during heavy rainfall.

  • What are the operating conditions of this product?

  • The operating conditions of the Ripen It! Gas Analyzer are 0°C – 50°C and 0 – 90% non-condensing humidity.

  • How many measurements can the included SD card hold?

  • The included 16gb SD card can hold approximately 60 million measurements. If saving data every minute, that equates to approximately 40,000 days of measurement before the SD card is full.

  • What types of tubing materials are recommended to avoid outgas interference.

  • Viton and Teflon have successfully been found not to outgas.

Have additional questions?

Click the link below to speak with one of our staff scientists about your specific application.

Specifications

Trigger Mode Measurements C2H4

Sensor Type: Electrochemical
Range: 0-1000 ppm
Resolution: 1 ppm
Lower Detection Limit: 10 ppm
Sampling Volume: 35 ml
Response Time: 35 seconds

Offset Calibration: WeeklySensor Replaceable (by user): yes

Accuracy (absolute): 10 ppm
Accuracy (relative): 5%
Span Calibration: 3 months
Lifetime: 1 years

Trigger Mode Measurements CO2

Sensor Type: Infrared Sensor, Pyroelectric detector
Range: 0-100%
Resolution: 0.01%
Lower Detection Limit: 0.50%
Sampling Volume: 12 ml
Response Time: 12 seconds

Offset Calibration: WeeklySensor Replaceable (by user): no

Accuracy (absolute): 0.50%
Accuracy (relative): 2%
Span Calibration: 12 months
Lifetime: 5 years

Trigger Mode Measurements O2

Sensor Type: Electrochemical
Range: 0-100%
Resolution: 0.10%
Lower Detection Limit: 0.30%
Sampling Volume: 12 ml
Response Time: 12 seconds

Offset Calibration: WeeklySensor Replaceable (by user): yes

Accuracy (absolute): 0.30%
Accuracy (relative): 3%
Span Calibration: 6 months
Lifetime: 2 years

Continuous Mode Measurements C2H4

Sensor Type: Electrochemical
Range: 0-1000 ppm
Resolution: 1 ppm
Lower Detection Limit: 2 ppm
Response Time: 90 seconds

Offset Calibration: WeeklySensor Replaceable (by user): yes

Accuracy (absolute): 2 ppm
Accuracy (relative): 5%
Span Calibration: 3 months
Lifetime: 1 years

Continuous Mode Measurements CO2

Sensor Type: Infrared Sensor, Pyroelectric detector
Range: 0-100%
Resolution: 0.01%
Lower Detection Limit: 0.01%
Response Time: 6 seconds

Offset Calibration: WeeklySensor Replaceable (by user): no

Accuracy (absolute): 0.01%
Accuracy (relative): 3%
Span Calibration: 12 months
Lifetime: 5 years

Continuous Mode Measurements O2

Sensor Type: Electrochemical
Range: 0-100%
Resolution: 0.10%
Lower Detection Limit: 0.10%
Response Time: 12 seconds

Offset Calibration: WeeklySensor Replaceable (by user): yes

Accuracy (absolute): 0.10%
Accuracy (relative): 2%
Span Calibration: 6 months
Lifetime: 2 years

x

F-960 Set-Zero (O2)

The F-960 Ripen It! Gas Analyzer quickly and accurately measures ethylene, CO2, and O2 to assist with decision making throughout the produce ripening process.

F-960 Set-Zero (CO2)

All three sensors work together to give you a clear picture of gas concentrations in ripening rooms.

F-960 Set-Zero (C2H4)

The Ripen It! is a handheld unit that can easily be transported into ripening rooms or connected to rooms through external ports.

F-960 Span Calibration

Data is conveniently transferred from the device to a network using Bluetooth or the removable
SD card.

Standard Gas Tank Attachment Tutorial

All three sensors work together to give you a clear picture of gas concentrations in ripening rooms. The Ripen It! is a handheld unit that can easily be transported into ripening rooms or connected to rooms through external ports.

Real-time ripening gas monitoring.

Quickly and confidently assess ethylene levels from 0-1000 ppm.