F-950 Three Gas Analyzer

Gather ethylene, CO2 and O2 data in seconds with the Felix Instruments Three Gas Analyzer.

Get to know your storage and ripening gasses.

Gather ethylene, CO2 and O2 data in seconds with the Felix Instruments Three Gas Analyzer.

F-950 Three Gas Analyzer

Backlit LCD screen

Never struggle to see your readings, even in dimly-lit storage environments.

Lightweight & heavy duty

Individually machined in the USA, the Store It! Gas Analyzer’s highly durable, aluminum construction gives you peace of mind without sacrificing weight.

Automated data capture

Never lose a data point with up-to-the-second autosave.

Internal data logging

Store and review thousands of records on the Three Gas Analyzer’s removable 16gb SD card.

F-950 Three Gas Analyzer
1

Backlit LCD screen

Never struggle to see your readings, even in dimly-lit storage environments.

2

Lightweight & heavy duty

Individually machined in the USA, the Store It! Gas Analyzer’s highly durable, aluminum construction gives you peace of mind without sacrificing weight.

3

Automated data capture

Never lose a data point with up-to-the-second autosave.

4

Internal data logging

Store and review thousands of records on the Three Gas Analyzer’s removable 16gb SD card.

Request a live demonstration

Portable gas analysis for commercial and research applications

Wide temperature and humidity range

Achieve pinpoint accuracy in your ethylene readings with the PolarCept! water
filter.

Remove non-ethylene hydrocarbons

Achieve pinpoint accuracy in your ethylene readings with the PolarCept! water
filter

All-day battery life

With an 8.5 hour battery life and rechargeable 3400 mAh replacement batteries
included, you can work confidently without interruption.

User-selected sampling modes

Choose from headspace or continuous sampling depending on your unique
needs.

5 data points recorded

Each sampling event records CO2 concentration, O2 concentration, date & time,
RH, and GPS location.

Painless data transfer

With bluetooth and WIFI capabilities, rapid data transfer has never been easier.

  • Does this product come with a warranty?

  • All devices from Felix Instruments – Applied Food Science come with a 12-month warranty at the point of sale. The warranty covers repairing and replacing defective parts of the instrument that were manufactured directly by Felix Instruments. The warranty does not cover wear and tear, neglect, misuse, accident, or excessive deterioration. Further, unauthorized repair and alteration by an unauthorized party voids the warranty. More information can be found in the operation manual of your instrument.

  • Is the Three Gas Analyzer waterproof?

  • The Three Gas Analyzer is not designed to be waterproof and should not be used underwater. The Three Gas Analyzer is designed to be water-resistant. Use in light rain is fine, however, there are electronics inside of the Three Gas Analyzer that can be damaged from water entering the instrument, so it is not recommended to use the Three Gas Analyzer during heavy rainfall

  • What are the operating conditions of this product?

  • The operating conditions of the Ripen It! Gas Analyzer are 0°C – 50°C and 0 – 90% non-condensing humidity.

  • How many measurements can the included SD card hold?

  • The included 16gb SD card can hold approximately 60 million measurements. If saving data every minute, that equates to approximately 40,000 days of measurement before the SD card is full.

  • What types of tubing materials are recommended to avoid outgas interference?

  • Viton and Teflon have successfully been found not to outgas.

Have additional questions?

Click the link below to speak with one of our staff scientists about your specific application.

Specifications

Trigger Mode Measurements C2H4

Sensor Type: Electrochemical
Range: 0-200 ppm
Resolution: 0.1 ppm
Lower Detection Limit: 0.15 ppm
Sampling Volume: 35 ml
Response Time: 35 seconds

Offset Calibration: WeeklySensor Replaceable (by user): yes

Accuracy (absolute): 2 ppm
Accuracy (relative): 5%
Span Calibration: 3 months
Lifetime: 2 years

Trigger Mode Measurements CO2

Sensor Type: Infrared Sensor, Pyroelectric detector
Range: 0-100%
Resolution: 0.01%
Lower Detection Limit: 0.50%
Sampling Volume: 12 ml
Response Time: 12 seconds

Offset Calibration: WeeklySensor Replaceable (by user): no

Accuracy (absolute): 0.50%
Accuracy (relative): 3%
Span Calibration: 12 months
Lifetime: 5 years

Trigger Mode Measurements O2

Sensor Type: Electrochemical
Range: 0-100%
Resolution: 0.10%
Lower Detection Limit: 0.30%
Sampling Volume: 12 ml
Response Time: 12 seconds

Offset Calibration: WeeklySensor Replaceable (by user): yes

Accuracy (absolute): 0.30%
Accuracy (relative): 2%
Span Calibration: 6 months
Lifetime: 2 years

Continuous Mode Measurements C2H4

Sensor Type: Electrochemical
Range: 0-200 ppm
Resolution: 0.1 ppm
Lower Detection Limit: 0.2 ppm
Response Time: 80 seconds

Offset Calibration: WeeklySensor Replaceable (by user): yes

Accuracy (absolute): 0.2 ppm
Accuracy (relative): 5%
Span Calibration: 3 months
Lifetime: 2 years

Continuous Mode Measurements CO2

Sensor Type: Infrared Sensor, Pyroelectric detector
Range: 0-100%
Resolution: 0.01%
Lower Detection Limit: 0.01%
Response Time: 6 seconds

Offset Calibration: WeeklySensor Replaceable (by user): no

Accuracy (absolute): 0.01%
Accuracy (relative): 3%
Span Calibration: 12 months
Lifetime: 5 years

Continuous Mode Measurements O2

Sensor Type: Electrochemical
Range: 0-100%
Resolution: 0.10%
Lower Detection Limit: 0.10%
Response Time: 12 seconds

Offset Calibration: WeeklySensor Replaceable (by user): yes

Accuracy (absolute): 0.10%
Accuracy (relative): 2%
Span Calibration: 6 months
Lifetime: 2 years

F-950 Set-Zero (O2)

The F-950 Three Gas Analyzer measures levels of Ethylene, CO2 and O2 to maintain optimal produce quality at every phase of the supply chain.

F-950 Set-Zero (CO2)

The F-950’s versatile design allows it to be be scaled to many environments, from cold storage to transportation container.

F-950 Set-Zero (C2H4)

Simple to operate and weighing less than a kilogram, the F-950 uses an electrochemical cell to measure ethylene between 0-200 ppm.

F-950 Span Calibration

The F-950 is ideal for measuring ethylene production across a wide range of fruit types.

Standard Gas Tank Attachment Tutorial

Versatile ethylene measurement from 0-200 ppm.

F-950 Three Gas Analyzer

Versatile ethylene measurement from 0-200 ppm.

Easily maintain optimal produce quality.