Easily maintain optimal produce quality
Versatile ethylene measurement from 0-200 ppm.
Controlled Atmosphere Facilities
Monitor ethylene mitigation and maintain the proper balance of gasses in controlled atmosphere environments.Ripening Rooms
Precision citrus degreening and ripening control on various commodities.Modified Atmosphere Packaging
QA assessment in packing lines, laboratories, import/export surveys, distribution centers and retail centers.Get to know your storage and ripening gasses.
Gather ethylene, CO2 and O2 data in seconds with the Felix Instruments Three Gas Analyzer.
Backlit LCD screen
Never struggle to see your readings, even in dimly-lit storage environments.
Lightweight & heavy duty
Individually machined in the USA, the Store It! Gas Analyzer’s highly durable, aluminum construction gives you peace of mind without sacrificing weight.
Automated data capture
Never lose a data point with up-to-the-second autosave.
Internal data logging
Store and review thousands of records on the Three Gas Analyzer’s removable 16gb SD card.
Request a live demonstration
Portable gas analysis for commercial and research applications
Wide temperature and humidity range
Achieve pinpoint accuracy in your ethylene readings with the PolarCept! water filter.
Remove non-ethylene hydrocarbons
Achieve pinpoint accuracy in your ethylene readings with the PolarCept! water filter.
All-day battery life
With an 8.5 hour battery life and rechargeable 3400 mAh replacement batteries included, you can work confidently without interruption.
User-selected sampling modes
Choose from headspace or continuous sampling depending on your unique needs.
5 data points recorded
Each sampling event records CO2 concentration, O2 concentration, date & time, RH, and GPS location.
Data transfer
Rapid data transfer through SD card and wired connection.
-
Does this product come with a warranty?
-
All devices from Felix Instruments – Applied Food Science come with a 12-month warranty at the point of sale. The warranty covers repairing and replacing defective parts of the instrument that were manufactured directly by Felix Instruments. The warranty does not cover wear and tear, neglect, misuse, accident, or excessive deterioration. Further, unauthorized repair and alteration by an unauthorized party voids the warranty. More information can be found in the operation manual of your instrument.
-
Is the Three Gas Analyzer waterproof?
-
The Three Gas Analyzer is not designed to be waterproof and should not be used underwater. The Three Gas Analyzer is designed to be water-resistant. Use in light rain is fine, however, there are electronics inside of the Three Gas Analyzer that can be damaged from water entering the instrument, so it is not recommended to use the Three Gas Analyzer during heavy rainfall
-
What are the operating conditions of this product?
-
The operating conditions of the Ripen It! Gas Analyzer are 0°C – 50°C and 0 – 90% non-condensing humidity.
-
How many measurements can the included SD card hold?
-
The included 16gb SD card can hold approximately 60 million measurements. If saving data every minute, that equates to approximately 40,000 days of measurement before the SD card is full.
-
What types of tubing materials are recommended to avoid outgas interference?
-
Viton and Teflon have successfully been found not to outgas.
Have additional questions?
Click the link below to speak with one of our staff scientists about your specific application.
Specifications
Trigger Mode Measurements C2H4
Sensor Type: | Electrochemical |
Range: | 0-200 ppm |
Resolution: | 0.1 ppm |
Lower Detection Limit: | 0.15 ppm |
Sampling Volume: | 35 ml |
Response Time: | 35 seconds |
Offset Calibration: | Weekly |
Sensor Replaceable (by user): |
Yes |
Accuracy (absolute): | 2 ppm |
Accuracy (relative): | 5% |
Span Calibration: | 3 months |
Lifetime: | 2 years |
Trigger Mode Measurements CO2
Sensor Type: | Infrared Sensor, Pyroelectric detector |
Range: | 0-100% |
Resolution: | 0.01% |
Lower Detection Limit: | 0.50% |
Sampling Volume: | 12 ml |
Response Time: | 12 seconds |
Offset Calibration: | Weekly |
Sensor Replaceable (by user): |
No |
Accuracy (absolute): | 0.50% |
Accuracy (relative): | 3% |
Span Calibration: | 12 months |
Lifetime: | > 15 years |
Trigger Mode Measurements O2
Sensor Type: | Electrochemical |
Range: | 0-100% |
Resolution: | 0.10% |
Lower Detection Limit: | 0.30% |
Sampling Volume: | 12 ml |
Response Time: | 12 seconds |
Offset Calibration: | Weekly |
Sensor Replaceable (by user): |
Yes |
Accuracy (absolute): | 0.30% |
Accuracy (relative): | 2% |
Span Calibration: | 6 months |
Lifetime: | 2 years |
Continuous Mode Measurements C2H4
Sensor Type: | Electrochemical |
Range: | 0-200 ppm |
Resolution: | 0.1 ppm |
Lower Detection Limit: | 0.2 ppm |
Response Time: | 80 seconds |
Offset Calibration: | Weekly |
Sensor Replaceable (by user): |
Yes |
Accuracy (absolute): | 0.2 ppm |
Accuracy (relative): | 5% |
Span Calibration: | 3 months |
Lifetime: | 2 years |
Continuous Mode Measurements CO2
Sensor Type: | Infrared Sensor, Pyroelectric detector |
Range: | 0-100% |
Resolution: | 0.01% |
Lower Detection Limit: | 0.01% |
Response Time: | 6 seconds |
Offset Calibration: | Weekly |
Sensor Replaceable (by user): |
No |
Accuracy (absolute): | 0.01% |
Accuracy (relative): | 3% |
Span Calibration: | 12 months |
Lifetime: | > 15 years |
Continuous Mode Measurements O2
Sensor Type: | Electrochemical |
Range: | 0-100% |
Resolution: | 0.10% |
Lower Detection Limit: | 0.10% |
Response Time: | 12 seconds |
Offset Calibration: | Weekly |
Sensor Replaceable (by user): |
Yes |
Accuracy (absolute): | 0.10% |
Accuracy (relative): | 2% |
Span Calibration: | 6 months |
Lifetime: | 2 years |
F-950 Set-Zero (O2)
F-950 Set-Zero (CO2)
F-950 Set-Zero (C2H4)
F-950 Span Calibration
Standard Gas Tank Attachment Tutorial
F-950 Three Gas Analyzer
Felix Instruments Handheld Gas Analyzer Series Live Training
Easily maintain optimal produce quality.
Gather ethylene, CO2 and O2 data in seconds with the Felix Instruments Three Gas Analyzer.
F-900DK Dynamic Sampling Kit
The Dynamic Sampling Kit allows users to take continuous measurements in closed environments with any of our handheld gas analyzers. The kit includes a 2L acrylic chamber (14cm diameter 12cm deep), wand attachment to connect chamber to the handheld gas analyzer, and battery pack to power fans in the chamber. Additional chamber option: 8L Chamber (24cm diameter 17cm deep).
9XX BE Battery Eliminator for Handheld Gas Analyzers
The Battery Eliminator allows for instruments to operate on AC power. Compatible with F-920, F-940, F-950, and F-960 gas analyzers.